3CW20,000A3

Designed  for use in:
  • Industrial heating applications
  • conventional plate-modulated amplifier
  • linear amplifier

 

Description
Maximum Ratings
Tube Numbering System
Warranty

Home
Products

Description

Plate Dissipation ( Max ) 20,000 watts
Grid Dissipation ( Max ) 250 watts
Frequency for Mas Ratings (CW) 110 watts
Cooling Water and Forced Air
Filament Thoriated Tungsten
     Voltage 7.5 volts
     Current 99.0 amperes
Capacitances ( Gnd. Cath. Connection )
     Input 53.0 pF
     Output 1.4 pF
     Feed-through 34.0 pF
Amplification Factor 20
Base  Coaxial
Recommended Air System Socket SK-1300
Maximum Seal and Anode Core Temperature 250o C
Maximum Length 11.22 in /  285.00 mm
Maximum Diameter 4.65 in / 118.10 mm
Weight ( approximate ) 11.5 lb / 5.2 kg
Operating Position Vertical, base up or down

(top)

 

 

Maximum Ratings Typical Operation
Class of Operation Type of Sevice Plate Voltage (volts) Plate Current (amps) Plate Voltage (volts) Plate Current (amps) Drive Power (watts) Output Power (watts)
C Grid Driven RF Amplifier 7000 4.0 7000 4.0 4100 24,500
C Grid Driven RF Amplifier Plate Modulated 5500 3.0 5000 3.0 515 12,400
C RF Industrial Oscillator 7000 4.0 7000 4.0 - 22,400
AB Cathode Driven RF Linear Amplifier 7000 5.0 70000 4.0 2050 20,000

(top)

USE OF THIS SITE INDICATES YOUR AGREEMENT TO THE
LEGAL TERMS AND RESTRICTIONS CONTAINED HEREIN.