Designed for use as a:
|
|
| Plate Dissipation ( Max ) | 30,000 watts |
| Grid Dissipation ( Max ) | 500 watts |
| Frequency for Max Ratings (CW) | 110 watts |
| Cooling | Water and Forced Air |
| Filament | Thoriated Tungsten |
| Voltage | 6.3 volts |
| Current | 160 amperes |
| Capacitances ( Gnd. Cath. Connection ) | |
| Input | 56.0 pF |
| Output | .2 pF |
| Feed-through | 36.0 pF |
| Capacitances ( Gnd. Grid Connection ) | |
| Input | 56.0 pF |
| Output | 36.0 pF |
| Feed-through | .2 pF |
| Amplification Factor | 200 |
| Base | Flexible filament leads |
| Maximum Seal Temperature | 250o C |
| Maximum Flexible Lead Temperature | 175o C |
| Maximum Length | 20.60 in / 524 mm |
| Maximum Diameter | 6.75 in / 171.40 mm |
| Weight ( approximate ) | 12 lb / 5.5 kg |
| Operating Position | Vertical, base up or down |
|
|
Maximum Ratings | Typical Operation | |||||
| Class of Operation | Type of Sevice | Plate Voltage (volts) | Plate Current (amps) | Plate Voltage (volts) | Plate Current (amps) | Drive Power (watts) | Output Power (watts) |
| C | Grid Driven RF Power Amplifier | 8000 | 5.0 | 7000 | 4.0 | 430 | 21,300 |
| AB | Cathode Driven RF Linear Amplifier | 8000 | 6.0 | 7000 | 5.0 | 1540 | 24,200 |
| A | Voltage Regulator | 28,000 | 6.0 | - | - | - | - |