| Designed for use primarily for use
as a amplifier in audio or RF applications
|
|
| Plate Dissipation ( Max ) | 10,000 watts |
| Grid Dissipation ( Max ) | 500 watts |
| Frequency for Mas Ratings (CW) | 160 watts |
| Cooling | Forced Air |
| Filament | Thoriated Tungsten |
| Voltage | 7.5 volts |
| Current | 99 amperes |
| Capacitances ( Gnd. Cath. Connection ) | |
| Input | 59.0 pF |
| Output | .2 pF |
| Feed-through | 36.0 pF |
| Capacitances ( Gnd. Grid Connection ) | |
| Input | 59.0 pF |
| Output | 36.0 pF |
| Feed-through | .2 pF |
| Amplification Factor | 200 |
| Base | Coaxial |
| Recommended Air System Socket | SK-1300 or SK-320 |
| Recommended Air Chimney | SK-1306 |
| Maximum Seal Temperature | 250o C |
| Maximum Flexible Lead Temperature | 175o C |
| Maximum Length | 8.75 in / 222.2 mm |
| Maximum Diameter | 7.05 in / 179.10 mm |
| Weight ( approximate ) | 12.0 lb / 5.5 kg |
| Operating Position | Vertical, base up or down |
|
|
Maximum Ratings | Typical Operation | |||||
| Class of Operation | Type of Sevice | Plate Voltage (volts) | Plate Current (amps) | Plate Voltage (volts) | Plate Current (amps) | Drive Power (watts) | Output Power (watts) |
| C | Cathode Driven REF Amplifier | 8000 | 4.0 | 7600 | 3.7 | 1510 | 22,500 |
| C | Grid Driven RF Amplifier Plate Modulated | 6500 | 3.0 | 5000 | 3.0 | 380 | 11,900 |
| AB | Cathode Driven RF Linear Amplifier | 8000 | 5.0 | 7000 | 5.0 | 1540 | 24,200 |
| AB | Cathode Driven RF Linear Amplifier AM Service | 8000 | 5.0 | 7000 | 2.4 | 330 | 5600 |
| AB | Grid Driven AF Amplifier or Modulator ( two tubes 0 | 8000 | 5.0 | 7000 | 10.0 | 560 | 47,700 |