3CX15,000A3

Designed  for use in:
  • industrial radio-frequency heating services
  • conventional plate-modulated amphilier
  • linear amplificaion 

 

Description
Maximum Ratings
Tube Numbering System
Warranty

Home
Products

Description

Plate Dissipation ( Max ) 15,000 watts
Grid Dissipation ( Max ) 500 watts
Frequency for Mas Ratings (CW) 100 watts
Cooling Forced Air
Filament Thoriated Tungsten
     Voltage 6.3 volts
     Current 160 amperes
Capacitances ( Gnd. Cath. Connection )
     Input 55.0 pF
     Output 1.4 pF
     Feed-through 34.0 pF
Amplification Factor 20
Base Coaxial
Recommended Air System Socket SK-1300
Recommened Air Chimney SK-1306
Maximum Seal and Anode Core Temperature 250o C
Maximum Length 8.75 in /  222.30 mm
Maximum Diameter 7.05 in / 179.10 mm
Weight ( approximate ) 12.0 lb / 5.5 kg
Operating Position Vertical, base up or down

(top)

 

 

Maximum Ratings Typical Operation
Class of Operation Type of Sevice Plate Voltage (volts) Plate Current (amps) Plate Voltage (volts) Plate Current (amps) Drive Power (watts) Output Power (watts)
C Grid Driven RF Amplifier 8000 6.0 8000 5.9 740 34,000
C Grid Driven RF Amplifier Plate Modulated 6500 5.0 5000 3.9 490 18,000
AB Grid Driven RF Linear Amplifier   8000 6.0 7000 4.8 215 23,000

(top)

USE OF THIS SITE INDICATES YOUR AGREEMENT TO THE
LEGAL TERMS AND RESTRICTIONSCONTAINED HEREIN.