| Created for use in amplifier, oscillator or modulator service. |
|
| Plate Dissipation ( Max ) | 5000 watts |
| Grid Dissipation ( Max ) | 150 watts |
| Frequency for Max. Ratings (CW) | 75 MHz |
| Cooling | Water orForced Air |
| Filament | Thoriated Tungsten |
| Voltage | 7.5 volts |
| Current | 51.5 amperes |
| Capacitances (Gnd. Cath. Connection) | |
| Input | 35.0 pF |
| Output | 0.9 pF |
| Feed-through | 20.0 pF |
| Amplification Factor | 22 |
| Base | Flexible Filament Leads |
| Maximum Seal Temperature | 250o C |
| Maximum Flexible Lead Temperature | 175o C |
| Maximum Length | 22.06 in / 560.30 mm |
| Maximum Diameter | 3.63 in / 92.10 mm |
| Weight ( approximate ) | 6.0 lb / 2.7 kg |
| Operating Position | Vertical, base up |
|
|
Maximum Ratings | Typical Operation | |||||
| Class of Operation | Type of Sevice | Plate Voltage (volts) | Plate Current (amps) | Plate Voltage (volts) | Plate Current (amps) | Drive Power (watts) | Output Power (watts) |
| C | Grid Driven RF Amplifier | 6000 | 2.5 | 6000 | 2.1 | 136 | 10,000 |
| C | Grid Driven RF Amplifier Plate Modulated | 5000 | 2.0 | 5000 | 1.5 | 76 | 5580 |
| AB | Grid Driven AF Amplifier or Modulator (two tubes) | 6000 | 2.5 | 5000 | 3.0 | 113 | 13,000 |
USE OF THIS
SITE INDICATES YOUR AGREEMENT TO THE
LEGAL TERMS AND RESTRICTIONS CONTAINED HEREIN.
Copyright © 2009 Zonum. All rights reserved.